What color is the AVGAS (F-18) clipboard?
Blue (with no stripes)
What term is used to describe the ability of a substance to support combustion?
Flammability
TO 00-25-172
When performing an RTB, due to variances in chemical properties and additive packages, defuel quantities shall not exceed what percentage of the return tank inventory?
10%
TO 42B-1-1
Which of the following has a Flash Point below 100 degrees Fahrenheit?
TS-1
TO 42B1-1-14
Which of the following is the JET A clipboard color scheme?
Yellow with White Stripes
DAFI 23-201
Before gauging a tank, personnel must wait a minimum of 30 minutes after completion of fuel receipts, transfers, or movements. Why?
To permit relaxation of electrostatic charges.
TO 37-1-1
What does the "2"" in 2F0X1 represent?"
The Logistics Career Group
DAFMAN 36-2100
What does the "F"" in 2F0X1 represent?"
The Fuels Career Field
DAFMAN 36-2100
Filter separators are designed with two stages, of which the second stage forms a barrier to cause the fallout of water. Which type of media are the second stage cartridges NOT made with?
Fiberglass
TO 37A-1-101
What is the only mobile Air Force equipment with micronic filters?
FORCE
TO 37A-1-101
For mobile refueling equipment, nozzles will be equipped with a strainer having a minimum of 60-mesh, but the nozzle shall be equipped with a 100-mesh strainer if the final filtration is more than how many feet from the nozzle?
120 ft
TO 37A-1-101
If aircraft sump samples reveal suspected contaminated aircraft fuels, who determines, using the appropriate guidance, if defuel operations shall occur?
FMT
TO 42B-1-1
Which SPR nozzle has the capability to perform as a straight throat or 45-degree nozzle?
D-3
TO 37A-1-101
If you are using a mechanical shaker for the separatory funnel, how often must you correlate results with the hand-shaking method?
Once a month
TO 42B-1-1
Fill in the blank: During fillstand bottom loading, the refueling unit operator will perform a high-level precheck operation within the first ___ gallons of fuel received.
500
TO 37-1-1
The four cycle, in-line 6 cylinder, turbocharged, aftercooler, diesel engine, when fully loaded will power the R-11 from 0-50 MPH in how many seconds?
92 to 95
TO 36A12-13-17-82
A non-resettable meter totalizer will record the total number of gallons of fuel flow up to ________.
99,999,999
TO 36A12-13-17-82
What is personnel management?
The management, planning, utilization, and deployment of personnel.
2F0X1 CFETP
2F0X1 CFETP 001
What is a SEI?
Identifiers of special experience and training not otherwise identified within the military personnel data system (MiLPDS).
DAFECD SECTION-III
2F0X1 CFETP 001
What publication provides a list of all SEIs and outlines requirements for each?
The Department of the Air Force Enlisted Classification Directory (DAFECD)
DAFECD SECTION-III
2F0X1 CFETP 001
What are the requirements to receive the 035 SEI, Forward Area Refueling Point (FARP)?
5-Skill Level, Completion of OJT, Medical clearance for flying or special operational duty status, FMT recommendation, AFSOC/A4RE Certification, and commander approval.
DAFECD SECTION-III
2F0X1 CFETP 001
What are the requirements to receive the 036 SEI, Cryogenics Specialist?
5-Skill level, Completion of OJT, Completion of Fuels Quality & Cryogenics Course, FMT recommendation, and commander approval.
DAFECD SECTION-III
2F0X1 CFETP 001
What are the requirements to receive the 039 SEI, Fuels Laboratory Technician?
5-Skill level, Completion of OJT, Completion of Fuels Quality & Cryogenics Course, FMT recommendation, and commander approval.
DAFECD SECTION-III
2F0X1 CFETP 001
What are the requirements to receive the 040 SEI, Fuels Accountant?
5-Skill level, Completion of OJT, Completion of Base Level Defense Fuels Management Course, FMT recommendation, and commander approval.
DAFECD SECTION-III
2F0X1 CFETP 001
What are the requirements to receive the 041 SEI, Special Fuels Handling-Ground (SFH-G)?
5-Skill level, Completion of OJT, Completion of Special Fuels Handling Ground Course, FMT recommendation, and commander approval.
DAFECD SECTION-III
2F0X1 CFETP 001
What are the requirements to receive the 369 SEI, Special Fuel Handling-Air (SFH-A)?
5-Skill Level, Completion of minimum OJT, Completion of Specialized Fuel Handling-Air Course, Medical clearance for flying or special operational duty status, FMT recommendation, AFSOC/A4RE Certification, and commander approval.
DAFECD SECTION-III
2F0X1 CFETP 001
What are the requirements to receive the 034 SEI, Bulk Fuel Operational Planner?
7-Skill Level, Completion of OJT, Completion of all mandatory courses and three elective courses, FMT recommendation, and commander approval.
DAFECD SECTION-III
2F0X1 CFETP 001
What is integrated defense?
The incorporation of multidisciplinary active and passive, offensive and defensive capabilities, employed to mitigate potential risks and defeat adversary threats to Air Force operations within the base boundary and the base security zone.
AFPD 31-1
2F0X1 CFETP 001
What is records management?
Planning, controlling, directing, organizing, training, promoting, and additional managerial activities involved with respect to records creation, maintenance, use, and disposition.
AFI 33-322
2F0X1 CFETP 001
What is a record?
All recorded information, regardless of form or characteristic, made or received by a federal agency under federal law.
AFI 33-322
2F0X1 CFETP 001
Who must effectively manage and protect Air Force record, information, and data?
All Department of the Air Force members.
AFI 33-322
2F0X1 CFETP 001
What publication outlines record maintenance procedures?
AFI 33-322 3.4, Records Management and Information Governance Program.
AFI 33-322
2F0X1 CFETP 001
What publication establishes guidance for publications and forms management DAF-wide?
DAFI 90-160, Publication and Forms Management.
DAFI 90-160
2F0X1 CFETP 001
What form is used to submit recommended changes and improvements to DAF/USAF/USSF publications?
DAF Form 847, Recommendation for Change of Product.
DAFMAN 90-161
2F0X1 CFETP 001
How would you propose recommended changes and improvements to DAF/USAF/USSF publications?
By submitting a DAF Form 847 to the OPR (Office of Primary Responsibility), or through the appropriate functional chain of command for higher headquarters publications.
DAFMAN 90-161
2F0X1 CFETP 001
What is the training system of record used to document and update the status of required training?
DAF Form 623, Individual Training Record Folder.
DAFMAN 36-2689
2F0X1 CFETP 001
What does the DAF Form 623, Individual Training Record Folder, contain?
The CFETP, AF JQS, DAF Form 797, or work center JQS (if applicable), DAF Form 623A or electronic equivalent, and CDC answer score sheets along with any locally determined requirements.
DAFMAN 36-2689
2F0X1 CFETP 001
What is the CFETP used for?
To plan, prioritize, manage, and execute training within the career field.
DAFMAN 36-2689
2F0X1 CFETP 001
What is the DAF Form 797?
A continuation of the CFETP, Part 2, or AF JQS.
DAFMAN 36-2689
2F0X1 CFETP 001
What is Product Inventory Management?
Predicting, forecasting, and ordering to maintain product levels.
2F0X1 CFETP
2F0X1 CFETP 002
What appropriate system is used to establish reports for consumption and demand planning, trend analysis, and submission?
BLSA (Base Level Support Applications) / FMD (Fuels Manager Defense) / Fuels Automation
EPOS ENTERPRISE
2F0X1 CFETP 002
What publication provides instructions for receipts, shipments, and bulk sales of Defense Working Capital Fund (DWCF) fuel and bulk fuel additives at Defense Fuel Support Points (DFSP)?
DLA Energy P-2.
DLA-E P-2
2F0X1 CFETP 002
What is Fuels Accounting?
Collecting, processing, and reconciling product transitions.
DAFI 23-201
2F0X1 CFETP 002
What publication provides instructions for obtaining and verifying information to complete product transactions?
DLA Energy P-1.
DLA-E P-1
2F0X1 CFETP 002
What applicable guidance is used to ensure transactions are billed correctly?
DLA Energy 2A Non-DoD DoDAAC Customer Listing
DLA ENERGY
2F0X1 CFETP 002
The publication provides guidance on the operating tolerance thresholds for the gain/loss of product inventory?
DLA Energy P-1 Table 1.
DLA-E P-1
2F0X1 CFETP 002
What publication provides the collection and transportation procedures for cash sale transactions?
DODM 4140.25 Vol 10 Section 7
DODM 4140.25
2F0X1 CFETP 002
What publication establishes usage, responsibilities, and procedures to prepare and administer Fuel Cards?
DLA Energy P-8.
DLA-E P-8
2F0X1 CFETP 002
What is equipment management?
The life cycle management of equipment to ensure the accurate control of property, documents, utilization, transportation, and record-keeping.
2F0X1 CFETP
2F0X1 CFETP 002
What is the data system used to track equipment authorizations and determine accountability?
Enterprise Logistics Management System (ELMS)/Defense Property Accountability System (DPAS)
DAFMAN 23-300
2F0X1 CFETP 002
What publication provides guidance on the functions, components, and theory of operations for cryogenic systems?
TO 37C2-8-24-1
TO 37C2-8-24-1
2F0X1 CFETP 003
What are the theory of operations for cryogenic transfer?
By attaching the service hose to another container and opening the pressure buildup valve to the coil, the coil provides a positive pressure to the tank as the liquid product is vaporized. Internal tank pressure forces transfer of the product.
TO 37C2-8-24-1
2F0X1 CFETP 003
What is gaseous oxygen?
A colorless, odorless, tasteless gas, 1.1 times heavier than air. It is not flammable; however, it will support the rapid combustion of most materials.
TO 42B6-1-1
2F0X1 CFETP 003
What is liquid oxygen?
A pale blue liquid, which exists in the liquid state only at an extremely low temperature (-182.5 C or -297 F).
TO 42B6-1-1
2F0X1 CFETP 003
What is gaseous nitrogen?
A colorless, odorless, tasteless gas, slightly lighter than air. It is inert and does not react with other substances nor will it support combustion.
TO 00-25-172
2F0X1 CFETP 003
What is liquid nitrogen?
A colorless, odorless liquid, which exists in the liquid state only at extremely low temperature (-196 C or -320.8 F).
TO 00-25-172
2F0X1 CFETP 003
What are the hazards of liquid oxygen?
Its characteristics can cause fire and explosions due to support and rapid combustion of all flammable material; high pressures, arising from confinement; and personal injury and equipment failure from extreme coldness.
TO 42B6-1-1
2F0X1 CFETP 003
What is the LOX servicing safety zone?
The area within 20 feet of pressurized LOX servicing equipment, servicing hose, aircraft servicing connection point or vents.
TO 00-25-172
2F0X1 CFETP 003
What publication provides detailed description and functionality of the R-11 and components?
TO 36A12-13-17-82
TO 36A12-13-17-82
2F0X1 CFETP 003
What are filter separators designed to do?
To extract solids and water from fuel during fuel movement.
TO 37A-1-101
2F0X1 CFETP 003
What are DP gauges for?
To indicate solids buildup on filter elements.
TO 37A-1-101
2F0X1 CFETP 003
What are the capabilities of the D-3 nozzle?
To perform as a straight throat or 45- degree nozzle. It can be used for both underwing and fuselage fuel servicing.
TO 37A-1-101
2F0X1 CFETP 003
What is a Deadman?
An electrically, hydraulically, mechanically, or pneumatically operated switch or valve requiring continuous positive hand pressure by the operator to maintain fuel flow.
TO 00-25-172
2F0X1 CFETP 003
What is the power take-off (PTO)?
A mechanical device that receives input power from the engine/transmission, which can then be diverted for driving and pumping operations.
TO 36A12-13-17-82
2F0X1 CFETP 003
What valve on the R-11 is used to stop fuel flow from the tank?
The Emergency Tank Shutoff Valve
TO 36A12-13-17-82
2F0X1 CFETP 003
What switch, located on the main pumping control panel of the R-11, will shut down the engine and pumping operations?
The Emergency Engine Stop Switch
TO 36A12-13-17-82
2F0X1 CFETP 003
What control allows the operator to adjust the engine speed during fuel servicing?
The Engine Auxiliary Throttle Control
TO 36A12-13-17-82
2F0X1 CFETP 003
What does the hose reel valve control do?
Allows deadman air to direct the opening or closing of the hose valve, which controls fuel flow to the hose reel.
TO 36A12-13-17-82
2F0X1 CFETP 003
What valve allows the operator to select between High-Flow, Low-Flow, and Defuel modes of operation?
The Main Control Panel Selector Valve
TO 36A12-13-17-82
2F0X1 CFETP 003
What is the Fuel Servicing Safety Zone (FSSZ)?
The area within 50 feet of a pressurized fuel carrying servicing component and 25 feet around aircraft fuel vent outlets.
TO 00-25-172
2F0X1 CFETP 003
What is electrical bonding?
Electrically connecting two or more components of a system to equalize voltage potential.
TO 00-25-172
2F0X1 CFETP 003
What is electrostatic grounding?
A path or means to remove any electrostatic charge buildup on a conductive object by connecting that conductive object to earth.
TO 00-25-172
2F0X1 CFETP 003
What operation is used to fill mobile refueling unit tanks?
Fillstand-Bottom Loading
TO 37-1-1
2F0X1 CFETP 003
What operation is used to transfer fuel from mobile refueling units to fuel storage tanks?
Return to Bulk (RTB)
TO 37-1-1
2F0X1 CFETP 003
What appropriate guidance provides instructions to prepare refueling units for transport and restoring them to fully operational capabilities after shipment?
TO 36A12-13-17-82 3.1
TO 36A12-13-17-82
2F0X1 CFETP 003
What is maintenance?
Preserving assets to continue providing service throughout life cycle.
2F0X1 CFETP
2F0X1 CFETP 003
What forms are used by operators to record any discrepancies found during inspections which requiring maintenance?
DAF Form 1800 and DAF Form 4427, Operator Inspection Guide and Trouble Report.
DAFI 24-302
2F0X1 CFETP 003
What publication provides detailed guidance on the use of tools?
TO 32-1-101
TO 32-1-101
2F0X1 CFETP 003
What is the purpose of the tool control program?
To prevent and eliminate FOD to aircraft, engines, missiles, training, and support equipment, and to reduce costs through strict effective control and accountability of assets.
DAFI 21-101
2F0X1 CFETP 003
Who is normally established at or within proximity of the Fuels Management compound and are the focal point for the labor, supplies and tools needed to support repairs and maintenance of the refueling vehicle fleet?
Refueling Maintenance (RFM)
DAFI 24-302
2F0X1 CFETP 003
What is quality assurance?
The aggregate of measures used to determine and maintain the quality of product receipts and Government owned bulk petroleum products to the degree necessary to ensure that such products are suitable for their intended use.
MIL-STD 3004D
2F0X1 CFETP 004
What applicable forms does Quality Compliance use to validate workplace compliance and processes.
AF2419 Routing and Review of Quality Control Reports, AF2420 Quality Control Inspection Summary, or electronic equivalent.
DAFI 23-201
2F0X1 CFETP 004
Which publications provide applicable standards to determine fuel grade specification?
TO 42B1-1-14 and TO 42B-1-1
TO 42B-1-1
2F0X1 CFETP 004
Which publication provides instructions for collecting and analyzing fuel samples?
TO 42B-1-1
TO 42B-1-1
2F0X1 CFETP 004
What is used to document fuel sample test results to conduct trend analysis?
Fuels Manager Defense (FMD)
DAFI 23-201
2F0X1 CFETP 004
What applicable guidance gives instruction for processing and shipping fuel and cryogenic samples for area lab testing?
TO 42B-1-1 5.1
TO 42B-1-1
2F0X1 CFETP 004
What actions should be taken in response to suspected contamination in fuel equipment/inventory?
Investigate and isolate affected equipment/inventory (external or internal) to allow proper notification.
TO 42B-1-1
2F0X1 CFETP 004
What is material contamination?
Material contamination consists of water, sediment, and
other materials within fuel systems.
TO 42B-1-1
2F0X1 CFETP 004
What is microbial contamination?
Microbial contamination is the growth of bacteria and/or fungi in water deposits within fuel systems.
TO 42B-1-1
2F0X1 CFETP 004
What is chemical contamination?
Chemical contamination is the result from mixing two different types of hydrocarbon fuels or mixing other chemicals with fuel.
TO 42B-1-1
2F0X1 CFETP 004
What is Work Center Safety?
Mitigating risk factors to prevent personnel injury and/or asset damage.
2F0X1 CFETP
2F0X1 CFETP 004
What is the purpose of the Air Force Mishap Prevention Program?
To minimize the loss of Air Force resources and protect Air Force personnel from death, injuries or occupational illnesses by managing risks on and off-duty.
2F0X1 CFETP
2F0X1 CFETP 004
What will work center/shop supervisors, USRs, and safety personnel perform to check the day-to-day safety and health of an organization, work center, facility, etc.?
Spot Inspections.
DAFI 91-202
2F0X1 CFETP 004
What methods can Airmen use to report hazards?
The AF Form 457, The Airmen Safety Action Program, and MAJCOM specific hazard reporting forms.
DAFI 91-202
2F0X1 CFETP 004
What type of hazards are the most common in the workplace?
Physical Hazards
DAFMAN 91-203
2F0X1 CFETP 004
What publication outlines Air Force Occupational Safety, Fire, and Health Standards?
DAFMAN 91-203, Air Force Occupational Safety, Fire, and Health Standards.
DAFMAN 91-203
2F0X1 CFETP 004
What is the purpose of the JSTO (Job Safety Training Outline)?
To instruct all employees on work place specific hazards upon initial assignment and when work conditions or tasks change.
DAFI 91-202
2F0X1 CFETP 004
What are methods of documenting JSTO training?
The AF Form 55, electronic mediums, or locally developed products.
DAFI 91-202
2F0X1 CFETP 004
What publication provides procedures and requirements for the collection, segregation, storage, and disposition of recoverable and waste petroleum products?
TO 42B-1-23
TO 42B-1-23
2F0X1 CFETP 004
What is reclaimable product?
Product of known or determinable quality that can be used for the original grade without reprocessing.
TO 42B-1-23
2F0X1 CFETP 004
What is recyclable product?
Product that does not meet its original purpose/grade and can be verified by AFPET laboratory analysis and remediated and used as the original purpose/grade or downgraded.
TO 42B-1-23
2F0X1 CFETP 004
What is waste product?
Product that is no longer suitable for any use on an installation because of excessive contamination or quality degradation.
TO 42B-1-23
2F0X1 CFETP 004
What fuels resources are used to identify past experiences for cause and prevention to mitigate future releases to recommend best practices?
Back to Basics and Mishap Reports.
2F0X1 CFETP
2F0X1 CFETP 004
What are the 5 steps of emergency management?
Prevention, prevention, response, recovery, and mitigation.
AFH 1
2F0X1 CFETP 004
What is the primary mission of the DAF Emergency Management(EM) Program?
To prevent, protect, prepare for, respond to, and recover from all hazards/threats that pose the greatest risk to lives, key resources, facilities, infrastructure, and operational missions.
AFH 1
2F0X1 CFETP 004
What are the important elements of an Emergency Response Plan?
Emergency contact information, initial response procedures, recovery operations, incident termination and follow-up actions, and training.
DLA-E ENVIRONMENTAL
2F0X1 CFETP 004
Emergency contact information in the Emergency Response Plan includes contact numbers for what facilities and/or organizations?
Contact numbers for the facility, fire department, relevant environmental regulators, local water supply and sewerage contacts, and specialized cleanup contractors.
DLA-E ENVIRONMENTAL
2F0X1 CFETP 004
The initial response procedures of the Emergency Response Plan should include what?
General information about emergency alarms, evacuation procedures, and emergency reporting.
DLA-E ENVIRONMENTAL
2F0X1 CFETP 004
Recovery operations of the Emergency Response Plan include what?
The activities that follow the initial emergency stage.
DLA-E ENVIRONMENTAL
2F0X1 CFETP 004
Incident termination and follow-up actions noted in the Emergency Response Plan should discuss what?
The demobilization of response resources and the timely maintenance and/or replacement of emergency response equipment that was deployed.
DLA-E ENVIRONMENTAL
2F0X1 CFETP 004
Who should be made aware of the Emergency Response Plan and should know their role if an emergency occurs?
All staff and contractors working at the facility.
DLA-E ENVIRONMENTAL
2F0X1 CFETP 004
What is the practical distinction of a small spill, as opposed to a large spill?
Small spills are those where the substance can be absorbed, neutralized, or otherwise controlled at the time of release by employees in the immediate release area or by maintenance personnel.
DLA-E ENVIRONMENTAL
2F0X1 CFETP 004
Where would you find a list of all state agency emergency response and spill notification numbers to contact when reporting a spill?
DLA Energy Environmental Guide for Fuels Facilities Appendix 2-2
DLA-E ENVIRONMENTAL
2F0X1 CFETP 004
What is readiness?
The assessment and preparation of personnel, equipment, infrastructure, and product inventories to fulfill assigned missions and tasks.
2F0X1 CFETP
2F0X1 CFETP 005
What is the practical distinction of a large spill, as opposed to a small spill?
DLA-E ENVIRONMENTAL
2F0X1 CFETP 004